Specification

Our Window and Door products are manufactured from Impact Modified PVC-U hollow chambered profiles. During the manufacuring process extruded profiles are quality inspected in accordance with CSTB, UATc, KIWA-KOMO & BBA certifications. Wymar Windows have been tested and approved by the Britsh Board of Agrèment under Assessment Report 1245.

WINDOW & DOOR PVC-U - TEST FIGURES
Mass Volume Kg/cm³ ISOR 1183 1.44 ± 0.02
Modulus of Elasticity MPa ISOR 178 2,500 ± 250
Ultimate Tensile Strength MPa ISOR 527 >/44
Elongation of Break %   >/150
Impact Test at -10ºC   UEATc-PVC <1 break/10
Tensile Impact mj/mm² ISOR 8256 >/600
Shrinkage at 100ºC % UEAtc-PVC <2;
VICAT Softening Temperature ºC ISO 306 80 ± 2
Ash Content % ISOR 1270 5.5 ± 0.3

REINFORCING
Where required, Wymar Windows and Doors are reinforced with galvanised steel sections or mill finish aluminium sections to the recommendations of our technical Department.

PRODUCT PERFROMANCE
Wymar Windows and Doors have been design tested to meet the requirements of BBA 1245 weather performance and functional testing.

EFFECTS OF FIRE ON PVC
Typical test results below, for rigid and flexible PVC compared to wood indicate that it is more difficult to ignite than wood.

PROPERTY TEST PVC-U FLEX.PVC-U WOOD
Flash ignition temperature ºC ASTM D 1929 400 330-380 210-270
Self ignition temperature ºC ASTM D 1929 450 420-430 400
Oxygen index % ISO 4589 50 23-33 21-23
ISO Rdiant Cone        
Ignition time (secs) at 30kw/m² ISO 5657 112 50-75 30-90
Ignition time (secs) at 50kw/m²   33 17-26 4-30
Needle flame test IEC 695-2-2 Non-ignitable Only ignitable at high plasticiser levels Ignitable in less than 20 secs